PV & Energy Storage System Parameters
Details
| Parameter / Model | Fit-110/50 | Fit-220/50 | Fit-200/50 | Fit-160/80 | Fit-320/80 | Fit-200/100 | Fit-410/100 |
| System Capacity (kWh) | 112.53 | 225.07 | 208.98 | 160.76 | 321.53 | 208.99 | 417.99 |
| System Rated Power (kW) | 50 | 50 | 50 | 80 | 80 | 100 | 100 |
| Stackable Battery Rack Model | Fit-110 | Fit-110 | Fit-200 | Fit-160 | Fit-160 | Fit-200 | Fit-200 |
| Stackable Battery Rack Quantity | 1 | 2 | 1 | 1 | 2 | 1 | 2 |
| Hybrid Inverter Model | EH50-IT-MX | EH50-IT-MX | EH50-IT-MX | EH80-IT-MX | EH80-IT-MX | EH100-IT-MX | EH100-IT-MX |
| Hybrid Inverter Rated Power (kW) | 50 | 50 | 50 | 80 | 80 | 100 | 100 |
| Hybrid Inverter Quantity | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Stackable Air-cooling Battery Rack Parameters
Details
| Technical Parameter | Fit-110 | Fit-160 | Fit-200 |
| Cell Type | LFP 314Ah | ||
| Pack Configuration | 1P16S | ||
| Pack Rated Voltage (V) | 51.2V | ||
| Pack Dimensions (W*H*D mm) | 445 × 248.5 × 851 mm | ||
| Pack Weight (kg) | 122 kg | ||
| Pack Capacity (kWh) | 16.07 kWh | ||
| Pack Quantity | 7 | 10 | 13 |
| Rack Capacity (kWh) | 112.53 kWh | 160.76 kWh | 208.99 kWh |
| Rack Rated Voltage (V) | 358.4V | 512V | 665.6V |
| Rack Voltage Range (V) | 313.6V ~ 397.6V | 448V ~ 568V | 582.4V ~ 738.4V |
| Rack Dimensions (W*H*D mm) | 910 × 1016.5 × 851 mm | 1365 × 1016.5 × 851 mm | 1820 × 1016.5 × 851 mm |
| Rack Weight (kg) | 950 kg | 1320 kg | 1700 kg |
| Ingress Protection | IP20 | ||
| Anti-corrosion Grade | C4-M | ||
| Operating Ambient Humidity | 5% ~ 85% | ||
| Operating Ambient Temperature | 0°C ~ 45°C | ||
| Max. Operating Altitude | ≤ 2000 m | ||
| Rack Cooling Method | Air-cooling | ||
| Communication Interface | CAN / LAN | ||
| Communication Protocol | CAN2.0B / Modbus TCP | ||
Hybrid Inverter Parameters
DC input (PV side)
| Technical Parameter | EH50-IT-MX | EH80-IT-MX | EH100-IT-MX |
| Recommended Max. PV Array Size | 100 kW | 160 kW | 200 kW |
| Max. Usable PV Input Power | 100 kW | 160 kW | 200 kW |
| Max. Input Voltage | 1000 V | ||
| Rated Voltage | 620 V | 600 V | 600 V |
| Start-up Voltage | 180 V | ||
| MPPT Voltage Range | 150 V ~ 950 V | ||
| Max. Input Current | 40 A × 4 / 40 A × 6 | 42 A × 10 | |
| Max. Short Circuit Current | 60 A × 4 / 60 A × 6 | 60 A × 10 | |
| Number of MPPT / Max. Input Strings | 4 MPPT / 8 strings | 10 MPPT / 20 strings | |
Battery
| Technical Parameter | EH50-IT-MX | EH80-IT-MX | EH100-IT-MX |
| Battery Type | LFP | ||
| Battery Voltage Range | 150 V ~ 950 V | 180 V ~ 950 V | |
| Max. Charging / Discharging Current | 160 A / 80 A × 2 | 200 A / 100 A + 100 A | |
| Number of Battery Ports | 1/2 | ||
| Max. Charging / Discharging Current per Port | 160 A / 80 A | 200 A / 100 A | |
| Communication | CAN / RS485 | ||
AC output (Emergency)
| Technical Parameter | EH50-IT-MX | EH80-IT-MX | EH100-IT-MX |
| Rated Output Power | 50 kW | 80 kW | 100 kW |
| Max. Apparent Output Power | 1.5 × rated power, 10s; 1.6 × rated power, 0.2s | 1.6 × rated power; 2 × rated power, 0.2s | |
| Emergency Switch Time | < 10 ms | ||
| Rated Output Voltage | 380 V / 400 V / 415 V, 3P4W | ||
| Rated Frequency | 50 Hz / 60 Hz | ||
| THDu (@ linear load) | < 3% | < 2% | |
AC input (Grid side)
| Technical Parameter | EH50-IT-MX | EH80-IT-MX | EH100-IT-MX |
| Max. Input Current | 182.3 A | 243.1 A | 300 A |
AC input (Generator)
| Technical Parameter | EH50-IT-MX | EH80-IT-MX | EH100-IT-MX |
| Rated Input Voltage | 380 V / 400 V / 415 V, 3P4W | ||
| Rated Input Frequency | 50 Hz / 60 Hz | ||
AC output (Grid side)
| Technical Parameter | EH50-IT-MX | EH80-IT-MX | EH100-IT-MX |
| Rated Output Power | 50 kW | 80 kW | 100 kW |
| Max. Apparent Output Power | 55 kVA | 88 kVA | 110 kVA |
| Rated Grid Voltage | 380 V / 400 V / 415 V, 3P4W | ||
| Rated Grid Frequency | 50 Hz / 60 Hz | ||
| Rated Grid Output Current | 76 A / 72.2 A / 69.6 A | 121.5 A / 115.5 A / 111.3 A | 151.9 A / 144.3 A / 139.1 A |
| Power Factor | > 0.99 (0.8 leading ~ 0.8 lagging) | > 0.99 (0.8 leading ~ 0.8 lagging) | |
| THDi | < 3% (Linear load < 1.5%) | < 2% | |
Efficiency
| Technical Parameter | EH50-IT-MX | EH80-IT-MX | EH100-IT-MX |
| Max. Efficiency | 98% | 97.8% | |
General specification
| Technical Parameter | EH50-IT-MX | EH80-IT-MX | EH100-IT-MX |
| Dimensions (W*H*D mm) | 600 × 970 × 290 mm | 971.5 × 880 × 311 mm | |
| Weight (kg) | 96 kg | < 150 kg | |
| Topology | Transformerless | ||
| Operating Ambient Temperature | -40°C ~ 60°C (derated over 45°C) | -40°C ~ 60°C (derated over 50°C) | |
| Relative Humidity | 0% ~ 95% RH | 0% ~ 100% RH | |
| Ingress Protection | IP66 | ||
| Cooling Method | Intelligent air cooling | ||
| Max. Operating Altitude | 4000 m (derated above 2000 m) | 4000 m (derated above 3000 m) | |
| Grid Connection Standard (Planned Targets) | EN 50549-1/-2, VDE-AR-N 4105, NTS 631, CEI 0-21, C10/11, NRS 097-2-1, TOR, G99, IEC 62116, IEC 61727, MEA, PEA, etc. | ||
| Safety / EMC Standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4 | ||
| Communication Interface | Standard: Wi-Fi + Bluetooth, CAN-BMS × 1, CAN-Parallel × 2, LAN, RS485-Meter, EMS-RS485×1, CAN-EMS×1, DRM, DI × 5, DO × 6; Optional: 4G (alternative to Wi-Fi, WIFI is default) | Standard: Wi-Fi + Bluetooth, CAN-BMS × 2, CAN-Parallel × 2, LAN, RS485-Meter, RS485, DRM, DI × 5, DO × 5; Optional: 4G (alternative to Wi-Fi, WIFI is default) | |
Key Highlights
Cost-Effective, Budget-Friendly
Lightweight stacking cuts overall project costs
Modular design lowers initial investment
Compact Modules for Flexible Deployment
Compact battery units reduce reliance on heavy lifting machinery
Easy on-site positioning adapts to any space constraints
Flexible Stacking, Scalable Capacity
Free stacking supports multi-rack parallel expansion for tailored capacity
External hybrid inverter fits diverse power demands
Streamlined O&M, Efficient Servicing
Independent layout allows quick isolation/replacement of faulty units
Layered air-cooling simplifies inspection & unit disassembly